inglés term or phrase:
Pass/Fail judgement
español translation:
criterio de Pasa/Falla
Added to glossary by
Ruth García
Feb 8, 2004 22:37
21 yrs ago
19 viewers *
inglés term
Pass/Fail judgement
inglés al español
Técnico/Ingeniería
Electrónica / Ing. elect.
HiPot tester
Contexto: manual sobre un comprobador de alta tensión (HiPot tester).
"It is equipped with devices for Pass/Fail Judgement, test results and remote control."
"It is equipped with devices for Pass/Fail Judgement, test results and remote control."
Proposed translations
(español)
4 +2 | establecer el criterio Pasa/Falla |
pablosan
![]() |
4 | criterio de límites pasa/falla (para comprobar el valor máximo/mínimo del potencial eléctrico) |
dawn39 (X)
![]() |
4 | Apto/Falla |
Adriana Torres
![]() |
Proposed translations
+2
43 minutos
Selected
establecer el criterio Pasa/Falla
... dispositivos para establecer el criterio Pasa/Falla, ...
Alternativamente: "..comprobar si el nivel de la medida es correcto/incorrecto,..."
Alternativamente: "..comprobar si el nivel de la medida es correcto/incorrecto,..."
4 KudoZ points awarded for this answer.
Comment: "Muchas gracias."
43 minutos
criterio de límites pasa/falla (para comprobar el valor máximo/mínimo del potencial eléctrico)
Hola, Ruth.
"Electric potential detector, device tester and method of detecting electric potential
Abstract
A control circuit 10 inputs a maximum value, which is read out of a resistor 22, to one of the input terminals of a comparator 14 by providing the maximum value to a D/A convertor 18 through a latch 16. The electric potential V, which is an object to be tested, is input to another input terminal of the comparator 14 through a hold circuit 12. The comparator 14 judges the magnitude of the value of the electric potential V by referring to the maximum value and outputs to the control circuit 10. The same operation is also performed for the minimum value.
**The pass/fail judgement** is performed for judging whether the value of the electric potential V is within an allowable range by the comparison with the maximum value and the minimum value. Furthermore, the control circuit 10 performs an A/D conversion of the electric potential V by reading out data D1-Dn from the resistor 20 one after another to gradually change the reference of a comparison. The same comparator 14 performs the **pass/fail judgement** and the A/D conversion, and thus the inconsistency does not occur".
¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨
Puerto digital flexible I/O con **limites de pasa/falla** e interfaces para manejadores de componentes. ...
Modelo 248: Fuente programable de alta tensión hasta 5KV. ...
www.idm-instrumentos.es/Medidores/
fuentes.htm
=======================
Saludos cordiales.
:)
"Electric potential detector, device tester and method of detecting electric potential
Abstract
A control circuit 10 inputs a maximum value, which is read out of a resistor 22, to one of the input terminals of a comparator 14 by providing the maximum value to a D/A convertor 18 through a latch 16. The electric potential V, which is an object to be tested, is input to another input terminal of the comparator 14 through a hold circuit 12. The comparator 14 judges the magnitude of the value of the electric potential V by referring to the maximum value and outputs to the control circuit 10. The same operation is also performed for the minimum value.
**The pass/fail judgement** is performed for judging whether the value of the electric potential V is within an allowable range by the comparison with the maximum value and the minimum value. Furthermore, the control circuit 10 performs an A/D conversion of the electric potential V by reading out data D1-Dn from the resistor 20 one after another to gradually change the reference of a comparison. The same comparator 14 performs the **pass/fail judgement** and the A/D conversion, and thus the inconsistency does not occur".
¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨¨
Puerto digital flexible I/O con **limites de pasa/falla** e interfaces para manejadores de componentes. ...
Modelo 248: Fuente programable de alta tensión hasta 5KV. ...
www.idm-instrumentos.es/Medidores/
fuentes.htm
=======================
Saludos cordiales.
:)
5 horas
Apto/Falla
El equipo cuenta con dispositivo Apto/Falla, resultados de la prueba y control remoto.