Entrada de glosario (tomada de la pregunta de abajo) | ||||||
---|---|---|---|---|---|---|
|
14:13 Oct 16, 2015 |
Traducciones de español a inglés [PRO] Tech/Engineering - Ingeniería: industrial | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Respuesta elegida de: Neil Ashby España Local time: 05:09 | ||||||
Grading comment
|
Resumen de las respuestas recibidas | ||||
---|---|---|---|---|
4 +2 | purging air blowers |
| ||
3 | purged air blowers |
|
purged air blowers Explicación: https://books.google.com/books?isbn=1420041215 W.F. Chen, J.Y. Richard Liew - 2002 - Technology & Engineering Purge air blowers with electrical resistance heaters are used for this purpose. ... in dry scrubbing systems, proper design of the hopper and solids discharge ... |
| ||
Notas al usuario que envió la respuesta
| |||
Login to enter a peer comment (or grade) |
purging air blowers Explicación: If it were "purged air" it would mean the air had been purged, whereas the actual situation is that the air is used for purging and so we get "purging air". Compare with "aire de sellado" - we don't say "sealed air" but rather "sealing air" - air used to create pressure and close a seal. See some examples: Catalog PA 01 • 2015 - Automation Technology - Siemens www.automation.siemens.com/sc-static/catalogs/.../PA01_en_K... Purging facilities on the process and the sensor sides, configurable application with purging gas connections for: - Instrument air. - ***Purging air blower***. - Steam. A5E00829151. A5E00829151. AIR BLOWER 230 V siemens71.ru/new/?fn=10030351_Z&art... Translate this page The purging gas flow is automatically set between 500 and <1 000 l/min on each sensor head depending on the ***purging air blower*** or the steam pressure. Download - MRU Instruments www.mru-instruments.com/ximages/1432694_mruinstrum.pdf mbar. 500 must exceed max. stack pressure. ***Purging air blower*** unit. 12.2" x 8.7" x 9.1". Air supply fitting. 1" BSP threaded aperture. Enclosure die cast aluminum. [PDF]DM 401 - MRU Instruments www.mru-instruments.com/ximages/1418363_dm401usabr.pdf Air supply pressure mbar. 500 must exceed max. stack pressure. Reflector. 6" x 4.8" x 4.7". Air supply fitting. 1" BSP threaded aperature. ***Purging air blower*** unit. Flyer DM 401 - MRU - Emission Monitoring Systems en.mru.eu/fileadmin/medien/produkte/...GB.../broschuere-dm-401.pdf Dust Monitoring System. Double pass transmission measurement. Measures 0 ... 100 % opacity. 3 or 10 ... 1.000 mg/m dust (*). DM 401. Purging air blower. [PDF]Continuous Gas Analyzers, in-situ www.sintrol.fi/images/Esitteet/LDS6_en.pdf Purging facilities on the process and the sensor sides, configurable application with purging gas connections for: - Instrument air. - Purging air blower. - Steam. [PDF]Catalog PA 01 • 2013 www.avigan.com.ua/library/2014pdf/ENG_112433.PDF Y30. Additional units. Order No. Purging air blower 230 V. A5E00829151. Purging air blower 115 V. A5E00829150. CD 6, sensor alignment kit. A5E00253142. |
| ||
Grading comment
| |||
Notas al usuario que envió la respuesta
| |||
Login or register (free and only takes a few minutes) to participate in this question. You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy. KudoZ™ translation helpLa red de KudoZ es un lugar de encuentro para que los traductores y otras personas interesadas se ayuden mutuamente con la traducción de términos y frases cortas.
See also: Search millions of term translations Your current localization setting