Spanish to English translations [PRO] Medical - Medical (general) / Pacemakers | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Neil Ashby Spain Local time: 08:28 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
4 +2 | ICD-CRT failure to capture |
| ||
4 | CRT-D loss of capture |
|
Summary of reference entries provided | |||
---|---|---|---|
Refs. - "AICD" (automatic/automated) or "ICD"? |
|
ICD-CRT failure to capture Explanation: https://ecgwaves.com/topic/assessment-of-pacemaker-malfuncti... Failure to capture — Genuine failure to capture occurs when a stimulus that is expected to result in activation fails to do so. This may be due to ... About featured snippets • Feedback People also ask What does it mean when a pacemaker fails to capture? What does capture mean in pacemaker? What causes failure to capture? What is failure to capture on ECG? Feedback Causes of Failure to Capture in Pacemakers and Implantable https://www.ncbi.nlm.nih.gov › articles › PMC7192127 by E Sabbagh · 2020 · Cited by 4 — An increase in the required threshold leading to a loss of capture can happen after months to years of insertion of the pacemaker or ICD. This ... Abstract · Introduction · Discussion Pacemaker Troubleshooting: Common Clinical Scenarios https://www.ncbi.nlm.nih.gov › articles › PMC5067035 by P Safavi-Naeini · 2016 · Cited by 18 — Capture failure occurs when the generated pacing stimulus does not initiate myocardial depolarization. On the surface ECG, pacing spikes are ... Pacemaker Malfunction • LITFL • ECG Library Diagnosis https://litfl.com › ECG Library Jun 4, 2021 — Problems with Pacing · Failure to capture occurs when paced stimulus does not result in myocardial depolarisation. · Multiple causes including ... Assessment of Pacemaker Malfunction – ECG & ECHO https://ecgwaves.com › Chapters Failure to capture — Genuine failure to capture occurs when a stimulus that is expected to result in activation fails to do so. This may be due to ... People also search for failure to capture pacemaker ecg failure to capture pacemaker treatment failure to capture treatment failure to capture pacemaker strip pacemaker oversensing pacemaker capture definition What causes a pacemaker to fail to capture? - Medscape https://www.medscape.com › answers › what-causes-a-pac... Oct 11, 2019 — Failure to capture occurs when a pacing artifact is not followed by an atrial or a ventricular complex (see the image below). Pacemaker Failure - an overview | ScienceDirect Topics https://www.sciencedirect.com › medicine-and-dentistry Pacemaker failure has three causes: (1) failure of capture, (2) lead failure, and (3) generator failure. Failure of capture owing to a defect at the level of ... Common pacemaker problems (part 1): Failure to capture https://www.youtube.com › watch Sep 16, 2015 — In today's teaching video, pacemaker expert Kristian Webb from the UK will explain:*What failure to capture is*Why it's important that you ... |
| ||||||||||||||||||
Grading comment
| |||||||||||||||||||
5 hrs confidence:
|
41 mins |
Reference: Refs. - "AICD" (automatic/automated) or "ICD"? Reference information: I think I understand your doubts and in no way am I opposing Neil Ashby's proposal. Links are diverse, if not inconsistent. In Spanish the term "automatic" is included which translates to "AICD", and both "AICD" and "ICD" on the net are common. DAI = desfibrilador automático implantable | **AICD** = automatic/automated implantable cardioverter defibrillator TRC = terapia de resincronización cardíaca | CRT = cardiac resynchronisation therapy So, **AICD-CRT failure to capture (FTC)** (1) loss of pacemaker capture following AICD discharge - PubMed https://pubmed.ncbi.nlm.nih.gov/2444945/ Abstract A 78-year-old man treated with amiodarone for recurrent ventricular tachycardia, had sequential placement of a bipolar VVI pacemaker and an **automatic implantable cardioverter defibrillator (AICD)**. During defibrillation threshold testing, there was failure to capture of the pacer in the post-shock period. The time of failure to capture appeared energy-related: the greater the energy delivered, the longer the failure to capture. (2) What does it mean when a pacemaker fails to capture? Failure to capture (FTC), which means that the pacemaker stimulations do not result in myocardial activation. Failure to pace (FTP), which means that the pacemaker does not stimulate as expected. Oversensing, which means that the pacemaker senses signals that are not true P-waves or R-waves. (3) What causes failure to capture? Failure to capture can result from several causes, including battery depletion, circuit failure, lead dislodgement or maturation, elevated capture thresholds due to progressive cardiac disease, metabolic abnormalities and or drugs. (4) How do you fix a pacemaker failure to capture? The typical treatment in this case is repositioning of the lead in the postoperative period. Patients who are dependent on pacing may require a temporary pacemaker or asynchronous pacing if there is just an acute increase in the threshold until lead repositioning. (5) https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7192127/ Causes of Failure to Capture in Pacemakers and Implantable Cardioverter-defibrillators Abstract The number of patients with implantable electronic cardiac devices is continuously increasing. As more pacemakers and implantable cardioverter-defibrillators (ICDs) are being placed, a basic understanding of some troubleshooting for devices is becoming essential. Loss of capture can be an emergent presentation for an unstable patient and can be encountered intermittently in hospitalized patients. There are many causes for a loss of capture, with the timing of the implant having a high correlation with certain causes over others. (6) http://www.emdocs.net/pacemaker-and-aicd-management-in-the-e... With the aging population and advances in the technological treatment of dysrhythmias and heart failure, a vast number of people are receiving **automated implantable cardiac devices (AICDs)**. In the United States, an estimated 370,000 people receive AICDs annually, and this number is anticipated to grow significantly (1). AICDs come in various models from standard single chamber pacemakers, biventricular pacemakers, to implantable cardioverter defibrillators (ICDs). **Says "automated" in this link (7) Automated implantable cardioverter defibrillator (AICD) - Healio https://www.healio.com/cardiology/learn-the-heart/cardiology... An **implantable cardioverter defibrillator (ICD or AICD)** is a permanent device in which a lead (wire) inserts into the right ventricle and monitors the heart ... **Automated Implantable Cardioverter Defibrillator (AICD) ** |
| |
Login to enter a peer comment (or grade) |