GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
20:00 Sep 11, 2007 |
Spanish to English translations [PRO] Tech/Engineering - Engineering: Industrial | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: bigedsenior Local time: 06:18 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
5 | two high voltage rotary cutters... |
| ||
4 +1 | Two rotary HV off-load [disconnector] switches |
| ||
5 | 2 high voltage rotary sectioning switched |
|
two high voltage rotary cutters... Explanation: Para cortar piedra se necesita potencia. De todos los seccionadores de probetas de piedra, la más rápida y eficiente es la rotatoria con canto diamantado. |
| |
Login to enter a peer comment (or grade) |
Two rotary HV off-load [disconnector] switches Explanation: Seccionador: Aparato de conexión mecánico que provee, en posición de apertura, una distancia de aislamiento de acuerdo con los requerimientos especificados. Nota: Un seccionador puede abrir o cerrar un circuito cuando se corta o establece una corriente insignificante. También es capaz de transportar corrientes bajo condiciones normales en el circuito y transportar durante un tiempo determinado corrientes en condiciones anormales como las de un cortocircuito. Un dispositivo mecánico de conexión y desconexión utilizado para cambiar las conexiones de un circuito, o para aislar un circuito o equipo de la fuente de alimentación. Nota: Está diseñado para permitir de manera permanente el paso la corriente de carga y también corrientes anormales debidas a cortocircuitos por tiempos cortos según especificación. Asimismo, debe maniobrarse sin carga o en vacío ya que sólo interrumpe la tensión no pudiendo hacerlo con la corriente. disconnector a mechanical switching device which provides, in the open position, an isolating distance in accordance with specified requirements NOTE – A disconnector is capable of opening and closing a circuit when either negligible current is broken or made, or when no significant change in the voltage across the terminals of each of the poles of the disconnector occurs. It is also capable of carrying currents under normal circuit conditions and carrying for a specified time currents under abnormal conditions such as those of short circuit. -------------------------------------------------- Note added at 2 hrs (2007-09-11 22:07:18 GMT) -------------------------------------------------- Ah and by the way, "seccionadores" is masculine (in Spanish) Reference: http://www.electropedia.org/iev/iev.nsf/SearchViewES/?Search... |
| |
Login to enter a peer comment (or grade) |
2 high voltage rotary sectioning switched Explanation: PLease read where it states that these switches are resistant to vibration and movement. http://www.rossengineeringcorp.com/hv_rotary_switches.htm -------------------------------------------------- Note added at 4 hrs (2007-09-12 00:41:28 GMT) -------------------------------------------------- ....sectioning switcheS -------------------------------------------------- Note added at 4 hrs (2007-09-12 00:42:30 GMT) -------------------------------------------------- ...or isolating switches.. |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.