GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
02:33 Jul 21, 2011 |
Japanese to English translations [PRO] Tech/Engineering - Energy / Power Generation | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Tatsuo Detake Japan Local time: 17:06 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
3 +2 | return valve |
| ||
4 | Recycle valve |
|
Recycle valve Explanation: 戻り弁はリサイクル弁 (RCV, recycle valve) という Reference: http://www.patentjp.com/19/O/O100012/DA10257.html |
| ||
Notes to answerer
| |||
Login to enter a peer comment (or grade) |
return valve Explanation: 日立製作所の特許公報から拾いました。 特開平07-229992 株式会社日立製作所 COOLING FACILITY FOR AIR RECIRCULATION SYSTEM OF REACTOR CONTAINMENT VESSEL 原子炉格納容器空気再循環系冷却設備 要約 子炉の格納容器空気再循環系(CAC)とサービス建屋換気系(SBV)の各冷却設備において、冷凍機の総設備容量と台数を低減する。 【構成】CAC側として格納容器9内の雰囲気温度を一定にするために熱除去を行う冷却器への冷水を供給する循環ポンプ1aの1台と冷却器3a~3dにて熱交換された冷水の熱除去を行う冷凍機2aの1台、SBV側として、建屋換気系の熱負荷、及びSBVの熱負荷、更に格納容器内の熱負荷を除去するための冷凍機4a~4cの3台、及び各負荷に冷水を供給する冷水循環ポンプ15a~15cの3台の機器と共通予備としてのCAC冷水循環ポンプ1b、冷凍機2b各1台、通常運転時のCAC内の熱負荷を除去するための流量調節弁17,遮断弁19、戻り弁16と建屋換気系へ冷水を供給するための流量調節弁13、及びCACとSBVの連絡用配管14から構成される。 Abstract: PURPOSE: To reduce the entire facility capacity and the number of refrigerators in each cooling facility of a containment vessel air recirculation system (CAC) and a service building ventilation system in a reactor. CONSTITUTION: In order to make atmosphere temperature of the inside of a containment vessel 9 constant, a recirculation pump 1a for supplying cooling water to coolers for performing heat removal and a refrigerator 2d for performing the heat removal of the heat-exchanged cooling water in the coolers 3a-3d are equipped. Three refrigerators 4a-4c for removing heat load of a building ventilation system, SBV, and the inside of the containment vessel as the side of SBV, a CAC cooling water circulation pump 1b and refrigerator 2b as common spare, a flow control valve 17, cutoff valves 19a, 19b and a return valve 16 for removing the heat load of the inside of CAC at the time of normal operation, a flow control valve 13 for supplying the cooling water to a building ventilation system 13 and tubing 14 for connecting CAC and SBV are constituted. |
| |
Login or register (free and only takes a few minutes) to participate in this question. You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy. KudoZ™ translation helpThe KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.
See also: Search millions of term translations Your current localization setting
English
Select a language Close search
|